Boiler Feed Pumps

Why are the stages being provided in Boiler Feed Pump?

Questions by shukla_vivek1011   answers by shukla_vivek1011

Showing Answers 1 - 3 of 3 Answers

sudeeb

  • Dec 19th, 2010
 

Boiler feed pump is a multi-stage centrifugal pump where no of impellers more than one usually >3 . Depending upon the boiler working pressure pump will select. The pump should have high positive suction to avoid cavitation, usually take more than 10m. feed water temperature will be more than>65'C.

  Was this answer useful?  Yes

kit_inton

  • Jun 19th, 2011
 

boiler feed pump stages deliver high discharge pressure from pump to overcome the pressure inside the boiler drum and pressure losses from pipe connections, and also friction loss.

  Was this answer useful?  Yes